Water Temperature Switch Inspection
• Remove the water temperature switch (see Water Temperature Switch Removal in the Cooling System chapter).
• Suspend the switch [A] in a container of coolant so that the temperature sensing projection and threaded portion are submerged.
• Suspend an accurate thermometer [B] in the coolant so that the sensitive portions [C] are located in almost the same depth.
NOTE
OThe switch and thermometer must not touch the container sides or bottom.
• Place the container over a source of heat and gradually raise the temperature of the coolant while stirring the coolant gently.
• Using the hand tester, measure the internal resistance of the switch across the terminal and the body at the temperatures shown in the table.
• If the hand tester does not show the specified values, replace the switch.
Water Temperature Switch Connections Rising temperature:
From OFF to ON at 113 ~ 117°C (235 ~ 243°F)
Falling temperature:
From ON to OFF at 108°C (226°F) temperature less than ON temperature