ELECTRICAL SYSTEM
Switches and Sensors
![]() |
Radiator Fan Switch Inspection
• Remove the left lower fairing (see Lower Fairing Removal in the Frame chapter).
• Remove the fan switch (see Radiator Fan Switch Removal in the Cooling System chapter).
• Suspend the switch [A] in a container of coolant so that the temperature-sensing projection and threaded portion are submerged.
• Suspend an accurate thermometer [B] in the coolant so that the sensitive portions [C] are located in almost the same depth.
NOTE
OThe switch and thermometer must not touch the container sides or bottom.
• Place the container over a source of heat and gradually raise the temperature of the water while stirring the water gently.
• Using the hand tester, measure the internal resistance of the switch across the terminals at the temperatures shown in the table.
• If the hand tester does not show the specified values, replace the switch.
Radiator Fan Switch Resistance Rising temperature:
From OFF to ON at 96 ~ 100°C (205 ~ 212°F)
Falling temperature:
From ON to OFF at 91°C (196°F)
Less than temperature at ON ON: Less than 0.5 Q OFF: More than 1 МП