Regulator Circuit Test-1st Step:
• Connect the test light and the 12V battery to the regulator/rectifier as shown.
• Check Y1, Y2, and Y3 terminal respectively.
• If the test light turns on, the regulator/rectifier is defective. Replace it.
• If the test light does not turn on, continue the test.
Regulator Circuit Test-2nd Step:
• Connect the test light and the 12V battery in the same manner as specified in the "Regulator Circuit Test-1st Step".
• Apply 12 V to the BR (voltage monitoring) terminal.
• Check Y1, Y2, and Y3 terminal respectively.
• If the test light turns on, the regulator/rectifier is defective. Replace it.
• If the test light does not turn on, continue the test.
Regulator Circuit Test-3rd Step:
• Connect the test light and the 12 V battery in the same manner as specified in the "Regulator Circuit Test-1st Step".
• Momentarily apply 24 V to the BR terminal by adding a 12 V battery.
Check Y1, Y2, and Y3 terminals respectively.